The binding models describe the fraction of one molecule bound by a
partner, such as a protein titrated with a ligand. The simple model,
"BK", assumes the limiting molecule is at a trace
concentration, so binding doesn’t use up the partner. When that isn’t
true, the quadratic model, "QBK", accounts for the
depletion. This example simulates a titration at three concentrations of
the limiting molecule, and compares the two models.
The variables
MODEL_VARIABLES[c("BK", "QBK")]
#> $BK
#> [1] "P" "FB"
#>
#> $QBK
#> [1] "P" "FB" "R"
MODEL_PARAMETERS[c("BK", "QBK")]
#> $BK
#> [1] "KD"
#>
#> $QBK
#> [1] "KD"-
Pis the total concentration of the partner in excess (the titrant). -
FBis the fraction of the limiting molecule that is bound, from 0 to 1. -
R(QBK only) is the total concentration of the limiting molecule. -
KDis the dissociation constant.
BK is FB = P / (P + KD). QBK solves the binding equilibrium exactly for given totals P and R, which gives a quadratic. When R is much smaller than KD the two agree. As R grows, more of the partner is used up in binding, so QBK’s curve shifts to higher P and changes shape.
Simulate a titration
Here KD is 1 µM, and the titration is repeated with the limiting molecule at 0.1, 1 and 4 µM:
set.seed(3)
data <- simulate_data("QBK", list(KD = 1), x.min = 0, x.max = 10, z.values = c(0.1, 1, 4),
n.samples = 12, noise.level = 0.03, noise.type = "absolute",
distribution = "truncated.norm")
make_plot("QBK", data.df = data, x.units = "µM", legend.label = "R (µM)")
The noise is absolute (a standard deviation of 0.03 in FB) and drawn
from a truncated normal distribution. FB can only be between 0 and 1,
and near full saturation ordinary normal noise would push some values
above 1. With distribution = "norm",
simulate_data() clips those to exactly 1 (with a warning),
so they pile up there. The truncated normal keeps every value in range
without the pile-up. Simulation
and noise has more on the choice.
Fit the quadratic model
fit_qbk <- fit_model("QBK", data, start.params = list(KD = 2), get.conf.int = TRUE)
fit_qbk$fitted.params
#> $KD
#> [1] 1.015479
#>
#> $KD.lb
#> [1] 0.95446
#>
#> $KD.ub
#> [1] 1.07882The estimate is close to the true KD of 1 µM.
fit_model() needs at least two different values of
R to fit QBK, and R must be greater than
0.
curves <- make_curve("QBK", fit_qbk$fitted.params, x.min = 0, x.max = 10, z.values = c(0.1, 1, 4))
make_plot("QBK", data.df = data, curve.df = curves, x.units = "µM", legend.label = "R (µM)")
Fit the simple model at each R
BK has no R, so fit it separately to each titration, as
you would if you ignored depletion:
kd_bk <- sapply(c(0.1, 1, 4), function(r) {
fit_model("BK", data[data$R == r, ], start.params = list(KD = 2))$fitted.params$KD
})
data.frame(R = c(0.1, 1, 4), KD_BK = round(kd_bk, 2), KD_QBK = round(fit_qbk$fitted.params$KD, 2))
#> R KD_BK KD_QBK
#> 1 0.1 1.06 1.02
#> 2 1.0 1.41 1.02
#> 3 4.0 2.35 1.02At R = 0.1 µM, a tenth of KD, the simple model is fine. As R grows, BK’s KD rises further above the true value. With depletion, half of the limiting molecule is bound when the total P is KD + R/2 rather than KD, so ignoring depletion makes binding look weaker than it is.
The R = 4 µM titration shows the mismatch. The BK fit (coloured) misses the shape that the QBK fit (black) follows:
r4 <- data[data$R == 4, ]
bk_fit <- fit_model("BK", r4, start.params = list(KD = 2))$fitted.params
make_plot("BK", data.df = r4,
curve.df = make_curve("BK", bk_fit, x.min = 0, x.max = 10),
extra.curve = make_curve("QBK", fit_qbk$fitted.params, x.min = 0, x.max = 10, z.values = 4),
x.units = "µM", title = "R = 4 µM: BK (coloured) and QBK (black)")
When to use which
If the limiting molecule is at a concentration well below KD, BK is
enough and needs only one titration. Otherwise use QBK, with titrations
at two or more concentrations of the limiting molecule. The binding
models allow only the standard and log10 plots, and their y-axis shows
FB from 0 to 1 unless you set y.range.
